What the EA402 Extension Cable Does

The EA402 is an extension cable used with TQ402 eddy current proximity probes and IQS450 signal conditioners in VM600 machinery protection systems. It carries the probe signal from the sensor to the signal conditioner. This cable is not a generic wire. It is part of a calibrated measurement chain.

Two common part numbers are:

  • 913-402-000-012 – EA402, 4.0 m cable, length code E040
  • 913-402-000-013 – EA402, 9.0 m cable, length code E090

Main Difference: Cable Length Only

The 012 and 013 cables use the same connector, same shielding design, and same electrical function. The only practical difference is physical length.

Item 913-402-000-012 913-402-000-013
Cable family EA402 EA402
Length code E040 E090
Cable length 4.0 m 9.0 m
Connector Same TQ402 / IQS450 mating Same TQ402 / IQS450 mating
Typical use Short runs, local conditioner cabinet Longer runs to remote cabinet or rack

If the original cable label shows E040, replace it with 913-402-000-012. If it shows E090, replace it with 913-402-000-013.

Why Cable Length Must Match the System

The TQ402 probe, EA402 cable, and IQS450 conditioner are calibrated as a set. Cable length affects the electrical matching of the eddy current probe loop. Changing from 4 m to 9 m can shift gap voltage and zero reference. That can cause false vibration readings or trip logic errors.

Do not use a longer cable just because it reaches the cabinet. After changing cable length, the system must be recalibrated.

When to Choose 4 m or 9 m

4 m cable, E040

  • Probe is mounted close to the IQS450 conditioner
  • Local junction box is near the machine
  • Gearbox, pump, or small motor monitoring with nearby cabinet
  • Easier routing in tight spaces

9 m cable, E090

  • Steam turbine bearing pedestal to remote cabinet
  • Long cable tray from machine to control room
  • Compressor or generator monitoring with distance to the rack
  • Existing installation already configured for 9 m

The choice is not based on preference. It depends on distance and original system configuration.

Installation and Signal Integrity

  • Keep the EA402 cable away from high-voltage power cables.
  • Do not pull, kink, or crush the cable.
  • Use proper cable glands at junction boxes.
  • Do not cut and splice the cable. Splicing changes impedance and damages system calibration.
  • If the shield is damaged, replace the cable. Signal noise can cause monitoring faults.

Buying and Replacement Checklist

Before ordering:

  1. Read the part number from the old cable label.
  2. Confirm the length code: E040 = 4.0 m, E090 = 9.0 m.
  3. Check the mating connector on the TQ402 probe and IQS450 conditioner.
  4. If the label is unreadable, measure the cable length and verify against the system BOM.
  5. Do not substitute a different EA402 length without system recalibration.

Joyoung International Trading Co., Limited supplies EA402 extension cables 913-402-000-012 and 913-402-000-013 for VM600 vibration monitoring systems. Both lengths are available with fast delivery.

FAQ

Can I use 913-402-000-013 instead of 913-402-000-012?
Only if the measurement chain is recalibrated for the 9 m cable. Otherwise gap voltage and trip thresholds may shift.

What does E040 or E090 mean?
It is the cable length code. E040 = 4.0 m, E090 = 9.0 m.

Are the connectors the same on both cables?
Yes. Both use the same connector for the TQ402 probe and IQS450 conditioner.

Can I extend a 4 m cable with another cable?
No. Adding cable changes the calibrated length and can cause measurement errors. Replace with the correct length.

How do I order the correct EA402 cable?
Contact Joyoung with the machine tag, existing part number, and required length code. Send a label photo if possible.

For EA402 913-402-000-012 or 913-402-000-013 stock and technical confirmation, email [email protected] or call +86-181-5013-7565.

If you’re interested, check out these related articles:

Industrial I O Module Types Digital Analog Communication Explained
Epro PR6424 002 100 Proximity Probe Replacement Specs

作者

xuansc2144

关注我
其他文章
上一个

Building Trust Across Cultures: A Practical Hardware Sourcing Guide for Central Asia

下一个

How Scent Affects Employee Productivity in Modern Offices

暂无评论!成为第一个。

发表回复 取消回复

您的邮箱地址不会被公开。 必填项已用 * 标注

近期文章

  • Central Asia Hardware Supply Chain: 2026 Buyer Opportunities
  • How Global Buyers Are Reshaping the 2027 Hardware Industry
  • How to Choose a Sanding Brush Roller: Abrasive Nylon vs Steel Wire
  • Healthcare Facility Fragrance Solutions for Patient Comfort
  • ICS Triplex T8480: How to Troubleshoot I/O Module Issues

近期评论

您尚未收到任何评论。

归档

  • 2026 年 10 月
  • 2026 年 9 月
  • 2026 年 8 月
  • 2026 年 7 月
  • 2026 年 6 月
  • 2026 年 5 月
  • 2026 年 4 月
  • 2026 年 3 月
  • 2026 年 2 月
  • 2026 年 1 月

分类

  • 上海绎维软件
  • 东抗生物
  • 中亚国际五金博览会CAIHE
  • 中国国际五金展CIHS
  • 丰筑
  • 华墨集团
  • 厦门泓鑫贺
  • 常州天展钢管
  • 昆明花展
  • 汇希
  • 辰献香氛
Copyright 2026 — 博客系统. All rights reserved. Blogsy WordPress Theme